Test Code HAIGM Hepatitis A Virus IgM Antibody, Serum


Necessary Information


Date of collection is required.



Specimen Required


Patient Preparation: For 24 hours before specimen collection, patient should not take multivitamins or dietary supplements (eg, hair, skin, and nail supplements) containing biotin (vitamin B7).

Collection Container/Tube: Serum gel (red-top tubes are not acceptable)

Submission Container/Tube: Plastic vial

Specimen Volume: 0.6 mL

Collection Instructions:

1. Centrifuge blood collection tube per manufacturer's instructions (eg, centrifuge and aliquot within 2 hours of collection for BD Vacutainer tubes).

2. Aliquot serum into plastic vial.


Secondary ID

48064

Useful For

Diagnosis of acute or recent hepatitis A infection

Special Instructions

Method Name

Electrochemiluminescence Immunoassay (ECLIA)

Reporting Name

Hepatitis A IgM Ab, S

Specimen Type

Serum SST

Specimen Minimum Volume

0.6 mL

Specimen Stability Information

Specimen Type Temperature Time Special Container
Serum SST Frozen (preferred) 90 days
  Refrigerated  6 days
  Ambient  72 hours

Reject Due To

Gross hemolysis Reject
Gross lipemia Reject
Gross icterus Reject
Heat-inactivated specimen Reject

Reference Values

Negative

See Viral Hepatitis Serologic Profiles.

Method Description

The Elecsys Anti-HAV (hepatitis A virus) IgM assay is based on the sandwich immunoassay principle and performed using an electrochemiluminescence immunoassay on the automated cobas e 801 immunochemistry analyzer. HAV-specific IgM antibody (anti-HAV IgM) in the patient’s serum sample is pretreated with anti-Fdy reagent to block specific IgG in the presence of monoclonal anti-HAV antibodies labeled with ruthenium complex. After addition of biotinylated monoclonal human-IgM-specific antibodies, HAV antigen, and streptavidin-coated microparticles, patient’s anti-HAV IgM form a sandwich complex with the HAV antigen and the ruthenium-labeled anti-HAV antibody which becomes bound to the solid phase via interaction of biotin and streptavidin. The reaction mixture is then aspirated into the measuring cell where the microparticles are magnetically captured onto the surface of the electrode, and unbound substances are washed away. Voltage is applied to the electrode then induces chemiluminescent emissions that are measured by a photomultiplier. Test result is determined automatically by the assay-specific software program by comparing the electrochemiluminescence signal generated from the patient’s sample to the cutoff index value set from reagent lot-specific assay calibration.(Package insert: Elecsys Anti-HAV IgM. Roche Diagnostics; v5.0, 11/2022)

Day(s) Performed

Monday through Saturday

Report Available

1 to 2 days

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Test Classification

This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.

CPT Code Information

86709

LOINC Code Information

Test ID Test Order Name Order LOINC Value
HAIGM Hepatitis A IgM Ab, S 13950-1

 

Result ID Test Result Name Result LOINC Value
HAIGM Hepatitis A IgM Ab, S 13950-1

Forms

If not ordering electronically, complete, print, and send 1 of the following:

-Gastroenterology and Hepatology Test Request (T728)

-Infectious Disease Serology Test Request (T916)