Test Code TEG-Plt Inh TEG- Platelet Inhibition
Aliases
TEG - Platelet Mapping
Useful For
The PlateletMapping cartridge consists of a set of blood modifiers, ADP and AA platelet agonists together with ActivatorF, which when used on a heparinized blood sample can measure the levels of platelet function. This assay specifically determines the MA (Maximum Amplitude, a measure of clot strength) and the reduction in MA due to genetics, surgical procedures, and/or antiplatelet therapy and reports it as a percentage of reduction in clot strength.
Patient Preparation
Avoid tissue contaminants or interfering substances, Using a 21 gauge needle or larger, venipuncture samples - draw 1 dark green top. Line draws discard the first 10mL of blood.
Collection Method
Use of 21 gauge or larger. Full tube. Mix well by inversion.
Minimum Volume
Tube filled to 1 mL Sodium Heparin (Green non-gel)
Container
Green Sodium Heparin (non-gel) vacutainer
Preferred Specimen
Green Sodium Heparin (non-gel) vacutainer
Reference or Target Ranges
PlateletMapping ADP+AA Assay Cartridge (07-614-US) | ||||||
HKH-MA (mm) | ActF-MA (mm) | ADP-MA (mm) | ADP-(% Inhib) | AA-MA (mm) | AA (% Inhib) | |
Normal Patient | 53-68 | 2-19 | 45-69 | 0-17 | 51-71 | 0-11 |
Reasons for Rejection
Hemolysis Threshold | N/A |
Icterus Threshold | N/A |
Lipemia Threshold | N/A |
Patient samples must be obtained through a 21-guage needed or larger. Underfilled , overfilled or clotted sample as well as samples that are refrigerated or centrifuged must all be redrawn. |
Specimen Stability
Ambient | 2 hours |
Refrigerated (4°C to 8°C) | N/A |
Frozen(-70°C to -20°C) | N/A |
Performance Information
Days and Time Performed | 24/7 |
Expected Turn Around Time |
Stat: Within 60 minutes of arrival in the lab Routine: Within 2 hours on arrival to lab |
Stat Availability | Yes |
Performing Bench | UH Coagulation |
Methodology/Method Description | The TEG6s analyzer records the kinetic changes in a sample of anticoagulated whole blood as the sample clots, retracts and/or lyses in real time. The system output consists of a table of numerical values derived from a graphical representation of the hemostasis curve, which depicts clot firmness over time. |
CPT Codes