Test Code VZVPV Varicella-Zoster Virus, Molecular Detection, PCR, Varies
Necessary Information
Specimen source is required.
Specimen Required
Submit only 1 of the following specimens:
Supplies: Sarstedt Aliquot Tube, 5 mL (T914)
Specimen Type: Body fluid
Sources: Spinal, pleural, peritoneal, ascites, pericardial, amniotic, or ocular
Container/Tube: Sterile container
Specimen Volume: 0.5 mL
Collection Instructions: Do not centrifuge.
Specimen Type: Swab
Sources: Miscellaneous; dermal, eye, nasal, or throat
Supplies:
-Culturette (BBL Culture Swab) (T092)
-M4-RT (T605)
Container/Tube: Multimicrobe media (M4-RT) and ESwabs
Collection Instructions: Place swab back into multimicrobe media (M4-RT, M4, or M5).
Specimen Type: Genital Swab
Sources: Cervix, vagina, urethra, anal/rectal, or other genital sources
Supplies:
-Culturette (BBL Culture Swab) (T092)
-M4-RT (T605)
Container/Tube: Multimicrobe media (M4-RT) (T605) and ESwabs
Collection Instructions: Place swab back into multimicrobe media (M4-RT, M4, or M5).
Specimen Type: Respiratory
Sources: Bronchial washing, bronchoalveolar lavage, nasopharyngeal aspirate or washing, sputum, or tracheal aspirate
Container/Tube: Sterile container
Specimen Volume: 1.5 mL
Specimen Type: Tissue
Sources: Brain, colon, kidney, liver, lung, etc.
Supplies: M4-RT (T605)
Container/Tube:
Preferred: Multimicrobe media (M4-RT)
Acceptable: Sterile container with 1 to 2 mL of sterile saline
Specimen Volume: Entire collection
Collection Instructions: Submit only fresh tissue in a sterile container containing 1 mL to 2 mL of sterile saline or multimicrobe medium (M4-RT, M4, or M5)
Secondary ID
618309Useful For
Rapid (qualitative) detection of varicella-zoster virus DNA in clinical specimens for laboratory diagnosis of disease due to this virus
This test should not be used to screen asymptomatic patients.
Method Name
Real-Time Polymerase Chain Reaction (PCR)/DNA Probe Hybridization
Reporting Name
Varicella-Zoster Virus, PCR, VariesSpecimen Type
VariesSpecimen Minimum Volume
Ocular Fluid and Spinal Fluid: 0.3 mL
Body Fluid (pleural, peritoneal, ascites, and pericardial): See Specimen Required
Respiratory Specimens: 1 mL
Tissue: 2 × 2 mm biopsy
Specimen Stability Information
Specimen Type | Temperature | Time | Special Container |
---|---|---|---|
Varies | Refrigerated (preferred) | 7 days | |
Frozen | 7 days |
Reject Due To
Calcium alginate-tipped swab Wood swab Transport swab containing gel Formalin-fixed and/or paraffin-embedded tissues Heat-inactivated specimen |
Reject |
Reference Values
Negative
Reference values apply to all ages.
Method Description
Viral nucleic acid is extracted by the MagNA Pure automated instrument (Roche Applied Science) from clinical specimens. Primers directed to target DNA (ss DNA binding proteins: gene 29) produce a 202-base pair amplicon. The LightCycler instrument amplifies and monitors by fluorescence the development of target nucleic acid sequences after the annealing step during PCR cycling. This is an automated PCR system that can rapidly detect (30-40 minutes) amplicon development though stringent air-controlled temperature cycling in capillary cuvettes. The detection of amplified products is based on the fluorescence resonance energy transfer hybridization probe with a donor fluorophore, fluorescein, on the 3' end is excited by an external light source and emits light that is absorbed by a second hybridization probe with an acceptor fluorophore, LC-Red 640, at the 5' end. The acceptor fluorophore then emits a light of a different wavelength that can be measured with a signal that is proportional to the amount of specific PCR product. Melting curve analysis is performed following PCR amplification. Starting at 45° C, the temperature in the thermal chamber is slowly raised to 80° C, and the fluorescence is measured at frequent intervals. Analysis of the PCR amplification and probe melting curves is accomplished through the use of LightCycler software.(Dhiman N, Wright PA, Espy MJ, Schneider SK, Smith TF, Pritt BS. Concurrent detection of herpes simplex and varicella-zoster viruses by polymerase chain reaction from the same anatomic location. Diagn Microbiol Infect Dis. 2011;70(4):538-540. doi:10.1016/j.diagmicrobio.2011.03.014; Espy MJ, Teo R, Ross TK, Scien KA, Wold AD, Smith TF. Diagnosis of varicella-zoster virus infections in the clinical laboratory by LightCycler PCR. J Clin Microbiol. 2000;38[9]:3187-3189)
Day(s) Performed
Monday through Saturday
Report Available
Same day/1 to 4 daysPerforming Laboratory
Mayo Clinic Laboratories in RochesterTest Classification
This test was developed and its performance characteristics determined by Mayo Clinic in a manner consistent with CLIA requirements. It has not been cleared or approved by the US Food and Drug Administration.CPT Code Information
87798
LOINC Code Information
Test ID | Test Order Name | Order LOINC Value |
---|---|---|
VZVPV | Varicella-Zoster Virus, PCR, Varies | 94584-0 |
Result ID | Test Result Name | Result LOINC Value |
---|---|---|
VZVS | Specimen Source | 31208-2 |
618332 | Varicella-Zoster Virus PCR | 94584-0 |
Forms
If not ordering electronically, complete, print, and send a Microbiology Test Request (T244) with the specimen.