Test Code ANA Prof ANA Profile
Useful For
Aids in the diagnosis of systemic autoimmune diseases
Patient Preparation
No special patient preparation required
Collection Method
Venous collection
Minimum Volume
3.5 mL
Container
Gold Top Serum Separator
Preferred Specimen
Serum
Acceptable Specimens
Serum:
- Gold Top SST
- Red Top
Plasma:
- Light Geen Top (lithium heparin)
Reference or Target Ranges
dsDNA | Negative | |
RNP | <20 RLU | |
Sm | <20 RLU | |
SSARo52 | <20 RLU | |
SSARo60 | <20 RLU | |
SSB | <20 RLU | |
Scl70 | <20 RLU | |
Jo-1 | <20 RLU |
Critical Value
Not defined for this assay
Reasons for Rejection
Hemolysis Threshold |
N/A |
Icterus Threshold |
N/A |
Lipemia Threshold |
N/A |
Other |
QNS, contaminated, improperly labeled, improper specimen type |
Specimen Stability
Ambient |
48 Hours |
Refrigerated (4°C to 8°C) |
14 Days |
Frozen(-70°C to 0°C) |
Indefinitely |
Performance Information
Days and Time Performed |
Monday – Friday 7 AM – 4 PM |
Expected Turn Around Time |
Within 7 days of arrival in lab |
Stat Availability |
No |
Performing Bench |
ANA |
Methodology/Method Description |
Manual and Bioflash – Indirect Immunofluorescence and Chemilluminescence |
CPT Codes
86255; 86256 (if appropriate)
Panel Components
- dsDNA
- RNP
- Sm
- SSARo52
- SSARo60
- SSB
- Scl70
- Jo-1
Reflex Testing
dsDNA reflex to titer if positive