Test Code Creat Cl Creatinine Clearance
Patient Preparation
No special patient preparation required
Special Collection Instructions
Requires the following:
- Collection of serum/plasma creatinine during time of 24 hour urine collection
- Patient’s current height in centimeters and current weight in kilograms to be entered by the ordering personnel at the time the test is ordered in the lab computer system.
Collection Method
24 Hour urine collection and Serum creatinine
Container
24 hour urine container
AND
Gold Top / Serum Separator / Additive Free
Preferred Specimen
Gold Top SST
Reference or Target Ranges
66 – 143 mL/min
Reportable Units
mL/min
Critical Value
Not defined for this assay
Reasons for Rejection
Hemolysis Threshold |
1000 mg/dL |
Icterus Threshold |
70 mg/dL |
Lipemia Threshold |
2000 mL |
Other |
QNS, contaminated, improperly Labeled, improper specimen type, Serum not collected during 24 hour urine collection, 24 hour urine collection information not included with specimen |
Specimen Stability
Ambient |
2 days |
Refrigerated (4°C to 8°C) |
6 days |
Frozen(-40°C to 0°C) |
6 months |
Performance Information
Days and Time Performed |
24/7 |
Expected Turn Around Time |
Stat: 1 hour Routine: 4 hours |
Stat Availability |
Yes |
Performing Bench |
UH Chemistry, WCH Chemistry |
Methodology/Method Description |
Roche Cobas – Enzymatic |
Additional Information/Important Notes
Creatinine clearance is calculated based on plasma and urine creatinine concentrations as well as the timed urine volume (24 hour urine).It is adjusted for patient height and weight. Please note that creatinine clearance is different from eGFR.
CPT Codes
82575