Test Code ETOH Ethanol Level
Aliases
Alcohol Level, Ethyl Alcohol
Patient Preparation
No special patient preparation required
Special Collection Instructions
IMPORTANT NOTE: DO NOT use alcohol or other volatile disinfectants at the site of venipuncture. Aqueous Zephiran (benzalkonium chloride), aqueous Merthiolate (thimerosal), or providone-iodine may be used.
Collection Method
Venous collection
Minimum Volume
0.6 mL
Container
Lt Green / Plasma Separator / Lithium Heparin
Preferred Specimen
Light Green Top (lithium heparin) plasma
Acceptable Specimens
Serum:
- Gold Top SST
- Red Top
Plasma:
- Light Geen Top (lithium heparin)
- Purple(K2 EDTA)
Reference or Target Ranges
<10 mg/dL
Reportable Units
mg/dL
Critical Value
>300 mg/dL
Reasons for Rejection
<!-- Rejection-->
Hemolysis Threshold | 200 mg/dL |
Icterus Threshold | 30 mg/dL |
Lipemia Threshold | 500 mL |
Other | QNS, contaminated, improperly Labeled, improper specimen type |
Specimen Stability
<!-- Stability -->
Ambient | 2 hours once opened and recapped, 2 days capped |
Refrigerated (4°C to 8°C) | 2 weeks capped |
Frozen(-40°C to 0°C) | 4 weeks |
Performance Information
<!-- Performance information -->
Days and Time Performed | 24/7 |
Expected Turn Around Time | Stat: 1 hour Routine: 4 hours |
Stat Availability | Yes |
Performing Bench | UH Chemistry, WCH Chemistry |
Methodology/Method Description | Roche Cobas – Enzymatic method with alcohol dehydrogenase |
Additional Information/Important Notes
Only good 2 hours once opened and recapped.
CPT Codes
82077