Test Code Influenza+SARS CoV2 (COVID-19)Rapid Antigen Combo Influenza+SARS Rapid Antigen Combo
Patient Preparation
N/A
Special Collection Instructions
N/A
Collection Method
Nasopharyngeal swab, nasal swab or swab that comes with the test kit
Container
Copan FLOQSwab
Preferred Specimen
Puritan Sterile Foam-tipped Swab
Acceptable Specimens
Nylon flocked nasopharangeal swab
Reference or Target Ranges
Negative
Reportable Units
Positive/Negative for each antigen
Critical Value
Not defined for this assay
Reasons for Rejection
Hemolysis Threshold | N/A |
Icterus Threshold | N/A |
Lipemia Threshold | N/A |
Other | QNS, contaminated, improperly labeled, improper specimen type |
Specimen Stability
Ambient | 48 hours |
Refrigerated (4°C to 8°C) | 48 hours |
Frozen(-40°C to 0°C) | N/A |
Performance Information
Days and Time Performed | 24/7 |
Expected Turn Around Time | Stat: 1 hour Routine: 4 hours |
Stat Availability | Yes |
Performing Bench | UH Chemistry, WCH Chemistry |
Routing Bench | UH Chem Man |
Instrument | Sofia 2 |
Methodology/Method Description | Sofia 2 SARS Antigen FIA - immunofluorescence technology in a sandwich design that is used with Sofia and Sofia 2 to detect nucleocapsid protein from SARS-CoV and SARS-CoV-2. This test alllows for the detection of SARS-CoV and SARS-CoV-2. The test detects but does not differentiate between the two viruses |
Additional Information/Important Notes
Negative results should be treated as presumptive. For SARS, confirmation with a molecular assay, if necessary for patient management, may be performed
CPT Codes
87428