Test Code Lytes Electrolyte Panel
Patient Preparation
No special patient preparation required
Collection Method
Venous collection
Minimum Volume
- Adults: 0.8 mL
- Pediatric: 0.5mL
Container
Lt Green / Plasma Separator / Lithium Heparin
Preferred Specimen
Light Green Top (lithium heparin) plasma
Acceptable Specimens
Serum:
- Gold Top SST
- Red Top
Plasma:
- Light Geen Top (lithium heparin)
Reference or Target Ranges
See individual test components for more information.
Reportable Units
mmol/L
Critical Value
See individual test components for more information.
Reasons for Rejection
Hemolysis Threshold | See individual tests |
Icterus Threshold | See individual tests |
Lipemia Threshold | See individual tests |
Other | QNS, contaminated, improperly labeled, improper specimen type |
Performance Information
Days and Time Performed | 24/7 |
Expected Turn Around Time | Stat: 1 hour Routine: 4 hours |
Stat Availability | Yes |
Performing Bench | UH Chemistry, WCH Chemistry |
Methodology/Method Description | Roche Cobas – Ion-Selective Electrode (ISE) |
Additional Information/Important Notes
See individual test components for more information
CPT Codes
80051
Panel Components
- Sodium
- Potassium
- Chloride
- CO2
- Anion Gap (Calc)