Test Code RF Panel Rheumatoid Factor Panel
Useful For
Aids in the diagnosis of Rheumatoid Arthritis
Patient Preparation
No special patient preparation required
Collection Method
Venous collection
Minimum Volume
2 mL
Container
Gold Top Serum Separator
Preferred Specimen
Serum
Acceptable Specimens
Serum:
- Gold Top SST
- Red Top
Plasma:
- Light Geen Top (lithium heparin)
Reference or Target Ranges
RF IgA | <20 |
RF IgM | <5 |
Reportable Units
RLU
Critical Value
Not defined for this assay
Reasons for Rejection
Hemolysis Threshold | N/A |
Icterus Threshold | N/A |
Lipemia Threshold | N/A |
Other | QNS, contaminated, improperly labeled, improper specimen type |
Specimen Stability
Ambient | 48 Hours |
Refrigerated (4°C to 8°C) | 14 Days |
Frozen(-70°C to 0°C) | Indefinitely |
Performance Information
Days and Time Performed | Monday – Friday 7 AM – 4 PM |
Expected Turn Around Time | Within 7 days of arrival in lab |
Stat Availability | No |
Performing Bench | ANA |
Methodology/Method Description | Bioflash – Chemilluminescence |
CPT Codes
82397 x2
Panel Components
- RF IgA
- RF IgM