Test Code Testos Testosterone Level Total
Patient Preparation
No special patient preparation required
Collection Method
Venous collection
Minimum Volume
- Adults: 1 ml
- Pediatric: 0.8 mL
Container
Lt Green / Plasma Separator / Lithium Heparin
Preferred Specimen
Light Green Top (lithium heparin) plasma
Acceptable Specimens
Serum:
- Gold Top SST
- Red Top
Plasma:
- Light Geen Top (Lithium heparin)
- Purple or Pink Top(K2/K3 EDTA)
Reference or Target Ranges
|
Female <50 Female >50 |
8 – 35 ng/dL 7 - 35 ng/dL |
|
Male <50 Male >50 |
197 – 669 ng/dL 187 - 684 ng/dL |
Reportable Units
ng/dL
Critical Value
Not defined for this assay
Reasons for Rejection
<!-- Rejection-->
| Hemolysis Threshold | 500 mg/dL |
| Icterus Threshold | 10 mg/dL |
| Lipemia Threshold | 1000 mg/dL |
| Other | QNS, contaminated, improperly Labeled, improper specimen type |
Specimen Stability
<!-- Stability -->
| Ambient | Not listed |
| Refrigerated (4°C to 8°C) | 7 days |
| Frozen(-40°C to 0°C) | 6 months |
Performance Information
<!-- Performance information -->
| Days and Time Performed | 24/7 |
| Expected Turn Around Time | Routine: 4 hours |
| Stat Availability | No |
| Performing Bench | UH Chemistry |
| Methodology/Method Description | Siemens Atellica - Immunoassay |
CPT Codes
84403