Test Code Fl Cnt Fluid Cell Count

Aliases

Cell Count Fluid

Useful For

Counts performed on many types of fluids from the body other than blood and often aid in giving more direct answers to what may be going on in a particular part of the body.

Patient Preparation

Sterile collection with specimen transported in a sterile container

Special Collection Instructions

Sterile, not clotted, properly labeled to include specimen source

Collection Method

Sterile collection

Minimum Volume

2 ml

Container

Sterile Cup

Preferred Specimen

Body Fluids (non CSF)

Acceptable Specimens

Body Fluids (non CSF)

Critical Value

Not defined for this assay

Reasons for Rejection

Hemolysis Threshold N/A
Icterus Threshold N/A
Lipemia Threshold N/A
Other Clotted; QNS, Contaminated; improperly labeled

Specimen Stability

Ambient Should be processed within 1 hour of collection. Due to the difficulty on obtaining these specimens, they will be counted whenever they arrive in the lab.
Refrigerated (4°C to 8°C) N/A
Frozen(-70°C to 0°C) N/A

Performance Information

Days and Time Performed 24/7
Expected Turn Around Time Stat within 1 hour of arrival to lab
Routine within 4 hours of arrival to lab
Stat Availabilty Yes
Performing Bench Uh Hematology
Methodology/Method Description Sysmex / Manual Differential – Sysmex device counts RBCs using electronic resistance detection. WBCs are evaluated using flow cytometry with a semiconductor laser exploiting the differences in size, complexity and RNA/DNA content. Manual differentials are performed by skilled laboratory techs.

Special Handling

Room Temp

CPT Codes

89050

Reflex Testing

Manual differential counts, Pathology QA reviews